Product Range
HCl Acid Inhibitor Sulfuric Acid Inhibitor (Rodine 130) Sulfamic Acid Inhibitor (Rodine 31A, Rodine 102) Hydrofluoric Acid Inhibitor (Rodine 51) Phosphoric Acid Inhibitor Citric Acid Inhibitor Acetic Acid Inhibitor, Formic Acid Inhibitor Sodium Bisulfate Corrosion Inhibitor Mono Ethylene Glycol Brine Corrosion Inhibitor Propylene Glycol Brine Corrosion Inhibitor Nitrite Based Glycol Brine Corrosion Inhibitor Calcium Chloride Brine Corrosion Inhibitor Methanol Brine Corrosion Inhibitor Engine Radiator Coolant Corrosion Inhibitor Cooling Tower Water Scale And Corrosion Inhibitor Cooling Water Zinc Phosphonate Corrosion Inhibitor Chiller Water Nitrite Based Corrosion Inhibitor Molybdate Phosphonate Corrosion Inhibitor Boiler Condensate Line Corrosion Inhibitor Boiler Water Ph Booster / Alkalinity Builder Boiler Catalyzed Oxygen Scavenger Hot Water Nitrite Based Corrosion Inhibitor Steel Pickling Corrosion Inhibitor Steel Pickling Corrosion Inhibitor For Sulfuric Acid Acid Pickling And Passivation Chemical Inhibited Propylene Glycol Bright Green Colored Inhibited Propylene Glycol Coil Cleaner Boiler Water Alkalinity Builder Poly Electrolyte Inhibited Sulfamic Acid Boiler Descalant Condenser Descalant Boiler Descalant Inhibited Ethylene Glycol
 |
Calcium Chloride Brine Corrosion Inhibitor |
|
Brines are very corrosive fluids and cause uniform corrosion and pitting corrosion. This happens because of their high chloride content, brine form hydrogen chloride or HCL acid and cause severe corrosion. Chemtex’s specialized brine corrosion inhibitor, successfully minimize corrosion in such high chloride brine system.
Brine water corrosion control chemical prevents corrosion by forming an orgaanic film on the metal surface. It successfully prevents corrosion of carbon steel (LTCS, HTCS), mild steel, stainless steel (of all types), copper and copper alloys.
|  |
Calcium Chloride Brine Corrosion Inhibitor

 | Corrosion Inhibitor For Calcium Chloride Brine The chloride compound brines from the house of CSL are of an extremely corrosive nature that becomes the cause of uniform corrosion and otherwise pitting corrosion. CSL is popular world-over for its high yield preparation of the solvent for the industry utility. We make use of high-end machines to insure accuracy of solutions. | Application | Brine System |
| | Specification | Chemical Type | Organic Chemical Compound | | Form | Liquid | | Specific Gravity | Ranges from 1.0 – 1.2 depending upon product | | pH | 12.5 + 1 | | Solubility | Completely Soluble in Brine |
|
| | Dosage | Brine Corrosion Inhibitor is normally fed continuously to the re-circulating closed system by injection dosing pump or dosed to the make-up tank. The amount of to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates will be specified by the CSL technical representative. |
| | Major Benefits | Minimum loss of metal or corrosion Excellent heat transferability and flow rate Long and extended life of Brine without fouling |
| |
|