HCl Acid Inhibitor Sulfuric Acid Inhibitor (Rodine 130) Sulfamic Acid Inhibitor (Rodine 31A, Rodine 102) Hydrofluoric Acid Inhibitor (Rodine 51) Phosphoric Acid Inhibitor Citric Acid Inhibitor Acetic Acid Inhibitor, Formic Acid Inhibitor Sodium Bisulfate Corrosion Inhibitor Mono Ethylene Glycol Brine Corrosion Inhibitor Propylene Glycol Brine Corrosion Inhibitor Nitrite Based Glycol Brine Corrosion Inhibitor Calcium Chloride Brine Corrosion Inhibitor Methanol Brine Corrosion Inhibitor Engine Radiator Coolant Corrosion Inhibitor Cooling Tower Water Scale And Corrosion Inhibitor Cooling Water Zinc Phosphonate Corrosion Inhibitor Chiller Water Nitrite Based Corrosion Inhibitor Closed Loop Chiller Water Nitrite Based Corrosion Inhibitor Molybdate Phosphonate Corrosion Inhibitor Boiler Condensate Line Corrosion Inhibitor Boiler Water Ph Booster / Alkalinity Builder Boiler Catalyzed Oxygen Scavenger Hot Water Nitrite Based Corrosion Inhibitor Steel Pickling Corrosion Inhibitor Steel Pickling Corrosion Inhibitor For Sulfuric Acid Acid Pickling And Passivation Chemical Inhibited Propylene Glycol Bright Green Colored Inhibited Propylene Glycol Coil Cleaner Boiler Water Alkalinity Builder Poly Electrolyte Inhibited Sulfamic Acid Boiler Descalant Condenser Descalant Boiler Descalant Inhibited Ethylene Glycol
 |
Chiller Water Nitrite Based Corrosion Inhibitor |
|
Closed Circuit Nitrite based corrosion inhibitor passivates the metal surface and prevents oxidation corrosion and galvanic corrosion in aerated chilled and hot water systems.Closed Loop or Closed Circuit Cooling or Heating Systems that use water for heat transfer must meet the following three mandatory requirements:- 1. Using Soft or DM water for feed and make up 2. An appropriate Corrosion Inhibitor with yellow metal protection, oxygen scavenger, added with antiscalant. 3. A suitable chlorine free Biocide for preserving water.
|  |
Closed Loop Chiller Water Nitrite Based Corrosion Inhibitor

 | Nitrite Based Corrosion Inhibitor For Closed Loop Chiller Water We have with us a high quality nitrite based chiller-water corrosion inhibitor that displays good passiveness with the metal surface and keeps oxidation corrosion and galvanic corrosion enclosed within closed loop chiller water systems. We make use of high-end machineries to ensure a good productivity. | Application | Engine Jacket, Chiller Water Circuit, Glycol Brine System, Hot Water Circuit, Engine Coolant, Process chilling & heating etc. |
| | Specification | Chemical Type | Organic Chemical Compound | | Form | Liquid | | pH | 12 + 1 | | Solubility | Completely Soluble in Water and glycol | | Dosage | Closed Loop Corrosion Inhibitor is normally fed continuously to the recirculating closed loop water system by injection dosing pump or dosed to the expansion tank. The amount of to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates will be specified by the Chemtex technical representative. |
| | Major Benefits | Minimum loss of system metal due to corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipments Long and extended life of Water without fouling |
| |
|