|
Product Range
HCl Acid Inhibitor Sulfuric Acid Inhibitor (Rodine 130) Sulfamic Acid Inhibitor (Rodine 31A, Rodine 102) Hydrofluoric Acid Inhibitor (Rodine 51) Phosphoric Acid Inhibitor Citric Acid Inhibitor Acetic Acid Inhibitor, Formic Acid Inhibitor Sodium Bisulfate Corrosion Inhibitor Mono Ethylene Glycol Brine Corrosion Inhibitor Propylene Glycol Brine Corrosion Inhibitor Nitrite Based Glycol Brine Corrosion Inhibitor Calcium Chloride Brine Corrosion Inhibitor Methanol Brine Corrosion Inhibitor Engine Radiator Coolant Corrosion Inhibitor Cooling Tower Water Scale And Corrosion Inhibitor Cooling Water Zinc Phosphonate Corrosion Inhibitor Chiller Water Nitrite Based Corrosion Inhibitor Molybdate Phosphonate Corrosion Inhibitor Molybdate-Phosphonate Corrosion Inhibitor Boiler Condensate Line Corrosion Inhibitor Boiler Water Ph Booster / Alkalinity Builder Boiler Catalyzed Oxygen Scavenger Hot Water Nitrite Based Corrosion Inhibitor Steel Pickling Corrosion Inhibitor Steel Pickling Corrosion Inhibitor For Sulfuric Acid Acid Pickling And Passivation Chemical Inhibited Propylene Glycol Bright Green Colored Inhibited Propylene Glycol Coil Cleaner Boiler Water Alkalinity Builder Poly Electrolyte Inhibited Sulfamic Acid Boiler Descalant Condenser Descalant Boiler Descalant Inhibited Ethylene Glycol
 |
Molybdate Phosphonate Corrosion Inhibitor |
|
Cooling Water Scale and Corrosion Inhibitors are chemical compounds that inhibit scale formation in the heat exchangers and prevent corrosion or rusting of heat exchangers at severe water conditions.
CHEMTEX’S range of Scale and Corrosion Inhibitor are effective in severe conditions of hard and saline make-up water from LSI of -4.0 to 4.0. These products are designed and best suited for Ship Condenser (once through system).
Antiscalants that are effective - are profitable for users for its round the year savings of power and labor, increase in production and extended system life. Use of anti-scalant is a prime necessity to meet up with the huge production targets.
Equivalent or even better than the followings:- INDION 9265 / INDION 4296 / INDION 4295 / INDION 4294 / INDION 4293 / INDION 4292 etc.
|  |
Molybdate-Phosphonate Corrosion Inhibitor

 | Closed Cooling System Molybdate-Phosphonate Corrosion Inhibitor The supreme molybdate phosphonate makes use of high quality corrosion inhibitors for the purpose of closed loop systems that prevent corrosion and scale deposition in aerated cooling water systems. The molybdate-phosphonate rust inhibitor encloses certain corrosion inhibitors that come utilized for steel, copper and copper. | Application | secondary cooling water systems of power plants, blast furnace cooling system, molds cooling in continuous casting mills process cooling and heating water systems of the chemical industry. |
| | Specification | chemical type | a stabilized blend of molybdate/phosphonate/azole and new generation chelants | | form | liquid | | ph | 10 + 1 | | solubility | completely soluble in water | | Dosage | molybdate phosphonate corrosion inhibitor is normally fed continuously to the re-circulating closed system by injection dosing pump or dosed to the expansion tank. The amount of to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates will be specified by the chemtex technical representative. |
| | Major benefits | minimum loss of metal excellent heat transferability and flow rate no need of descaling closed circuit equipments long and extended life of liquid without fouling |
| |
|